BEFORE USE
1. Before using this product, read the instruction manual completely and familiarize
yourself thoroughly with the product, its components and recognize the hazards
associated with its use.
2. Verify that the product and the application are compatible. Inspect before each
use. Do not use if bent, broken, leaking or damaged components are noted.
3. Replace worn or damaged parts and assemblies with BVA Hydraulics Authorized
Replacement Parts only (See Replacement Parts Section). Lubricate as
instructed in Maintenance Section.
4. Ensure method of conrming load is accurate and working properly. Have gauge
or load cell accuracy veried by qualied personnel on a yearly basis.
5.
Pumps should be stored where protected from the elements, abrasive dust,
and damage. Pumps can be stored horizontally or vertically.
SETUP
1. Prepare the pump for use:
A) For Models P350, P1000 & P1000AD:
Pull spring loaded lock pin, pivot toward rear to unlock the handle (Fig. 5).
Remove shipping plug and replace with air vent plug (Fig. 6).
Pull vent plug stem upward before use, press down when moving or storing
the pump (Fig. 7).
B) For Model P601S:
Push the handle lock latch to unlock the pump handle (Fig. 8).
C) For Model P2001:
Pull spring loaded lock pin pivot toward rear to unlock the handle (Fig. 5).
2. Carefully remove the threaded plug from oil outlet port.
3. Connect coupler, tting or hose of matching threads. Install in-line pressure
gauge.
NOTICE: Use an approved, high-grade pipe sealant to seal all hydraulic
connections
4. Check for leaks in system and have repaired by qualied personnel as needed.
Before repairs are made, depressurize system by opening the release valve
counterclockwise, but no more than 2 full turns.
OPERATION
WARNING: ALWAYS monitor pressure, load or position using suitable
equipment. Pressure may be monitored by means of an optional manifold
and gauge. Load may be monitored by means of a load cell and digital
indicator. Correct application position can only be determined by the operator
of the equipment.
1. Connect the pump to suitable application.
2. Ensure the oil level is correct and the system ttings and connections are leak
free before operating the pump.
3. Pump may be used in horizontal and vertical position
as illustrated on Figure 9.
4. Close release valve by turning it clockwise. Finger tight ONLY. Using tools on
release valve can damage it and cause the pump to malfunction.
5. Pump handle until desired pressure, load or position is reached.
6. Pressure will maintain until the release valve is opened.
7. To retract application, turn the release valve knob slowly counterclockwise
(never more than 2 full turns).
WARNING: NEVER operate pump with release valve closed and
disconnected from application. If operated in this condition, the hose and
connections become pressurized. This increases burst hazard. Damage
may occur to pump and its components.
4
Figure 6 -
Remove shipping plug and
replace with air vent plug before initial use.
Figure 7 -
Pull stem upward before use,
press down when moving or storing pump.
Figure 8 -
Push the handle lock latch to
unlock the pump handle.
Figure 5 -
Pull spring loaded lock pin, pivot
toward rear to unlock pump handle.
Figure 9 - Horizontal and Vertical Position
!
!