Bva-hydraulics HDC15008 Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
4
SPECIFICATIONS
Model
Number
Cylinder
Capacity
(tons)
Stroke
(in)
Internal
Pressure
at
Capacity
(psi)
Oil Capacity
(in
3
)
Collapsed
Height
(in)
Extended
Height
(in)
Weight
(lbs)
Center
Hole I.D.
(in)
Collar
Thread
Ram
O.D.
(in)
PUSH PULL PUSH PULL
HDC3007
30 20
7.00
10000
44.31 27.74 13.02 20.02 43.0
1.31
4
1
/
2
”-12
2.48
HDC3010 10.13 64.15 40.16 17.00 27.13 56.7 4
1
/
2
”-12
HDC6003
60 44
3.50 45.75 30.49 9.77 13.28 65.7
2.13
6
1
/
4
”-12
3.62HDC6006 6.50 84.81 56.53 12.76 19.26 81.1 6
1
/
4
”-12
HDC6010 10.12 132.10 88.04 17.25 27.37 112.4 6
1
/
4
”-12
HDC10001
100 71
1.50 33.23 21.18 6.50 8.00 73.7
3.11
-
4.92
HDC10003 3.00 66.47 42.37 10.00 13.00 113.3 8
3
/
8
”-12
HDC10006 6.00 132.39 84.73 13.49 19.49 153.2 8
3
/
8
”-12
HDC10010 10.13 224.52 143.11 18.14 28.27 198.9 8
3
/
8
”-12
HDC15008 150 82.8 8.00 259.19 132.44 13.75 21.75 239.2 3.94 - 5.91
OPERATION
Operate the hydraulic pump to advance and retract the cylinder.
Do not continue pumping when cylinder is fully extended. Internal
pressure will build up and may damage the seal of the cylinder.
WARNING: NEVER rely on hydraulic pressure alone to
secure a load! NEVER allow personnel to work or pass under
a load until the load is secured by cribbing, blocking, or other
mechanical means.
WARNING: To help prevent material fatigue if the cylinder
is to be used in a continuous application, the load should not
exceed 85% of the rated capacity.
WARNING:
Your cylinder, hose(s), couplings and pump all must
be rated for the same maximum operating pressure, correctly
connected and compatible with the hydraulic uid used. An
improperly matched system can cause the system to fail.
WARNING: All personnel must be clear before lowering load.
MAINTENANCE
1. Inspect hoses and connections daily. Replace damaged
components immediately with BVA Hydraulics Replacement
Parts only.
2. Tighten connections as needed. Use pipe thread sealing
compound when servicing connections.
3. Always use clean, approved hydraulic uid and change as
recommended or sooner if the uid becomes contaminated
(never exceed 400 hours). Follow pump manufacturers
instructions for changing and adding hydraulic uid. Use only
good quality hydraulic uid. We recommend Mobil DTE13M
or equivalent when using with hand pump or air pump; BVA
Hydraulics Oil (F01) or equivalent when using with electric pump.
Never use brake uid, transmission uid, turbine oil, motor oil,
alcohol, glycerin etc. Use of other than good quality hydraulic
oil will void warranty and damage the cylinder, pump, hose etc.
4. Use an approved, high-grade pipe thread sealant to seal all
hydraulic connections. Teon tape can be used if only one layer
of tape is used and it is applied carefully (two threads back) to
prevent the tape from being introduced into hydraulic system.
A piece of tape could travel through the system and obstruct the
ow of uid and adversely affect function.
Lubrication & Cleaning
Keep cylinder clean at all times.
1. Any exposed threads (male or female) must be cleaned and
lubricated regularly, and protected from damage. Lubricate with
light machine oil.
2. If a cylinder or ram has been exposed to rain, snow, sand,
airborne abrasive, or any corrosive environment, it must be
cleaned, lubricated, and protected immediately after exposure.
Daily clean exposed ram with clean cloth dampened with light
machine oil. Protect exposed ram from the elements at all times.
3. Keep the hydraulic system as free of dirt as possible. When
not in use, couplers must be sealed with dust covers. All hose
connections must be free of dirt and grime. Any equipment
attached to the cylinder must be kept clean.
Storage
Cylinders should be stored vertically with ram plunger fully retracted
in a dry, protected area, not exposed to corrosive vapor, dust or
other harmful elements. When a cylinder has not been used for
a period of 4 months, it should be connected to a pump and fully
extended and then retracted a minimum of 5 times. This cycle will
lubricate the cylinder wall, reducing the possibility of corrosion and
damage thereof.
How to remove faulty coupler:
If cylinder does not retract,
1. Secure load by other means.
2. Depressurize pump and hose.
3. Remove the cylinder from application.
4. Disconnect and replace with new coupler.
!
!
!
!